Delphi Fittings Group DELPHI FITTINGS GROUP Delphi Fittings Group · DIN 3015 Pipe Support Systems Division · DIN 3015 Hydraulic Pipe Support Systems Division
EN · 中文 · ES
ENGINEERING DESIGN REFERENCE · DIN 3015 METROLOGY

Pipe Clamping Materials, Torques & Spacing Guide

Technical engineering reference derived from Delphi Clamps factory catalogue pages 22–24 and 114. Comprehensive mechanical properties of clamp polymers and alloys, DIN 3015 Part 10 bolt tightening torques, axial holding loads, pipe span distance tables, and metal anti-corrosion coating options.

DIN 3015 Part 10 Torque Compliant
Axial Holding Loads up to 244.5 kN
UL94-V0 Fire Safety Verified
100% XRF Positive Material Identification
DIN 3015 Clamp Body Assembly & Component Matrix
DIN 3015 Assembly & Component Matrix

Standardized Clamp Bodies, Weld Plates, Cover Plates & Fasteners

POLYMER & ALLOY CHARACTERISTICS · RAW MATERIAL METROLOGY

Clamp Body Material Comparison & Operating Envelope

Carefully select your clamp body material based on continuous operating temperatures, chemical exposure (hydraulic oils, seawater, diesel fuel), and statutory fire safety requirements.

Material Type Standard Color Density (g/cm³) Tensile Strength (MPa) Flexural Modulus (MPa) Continuous Temp Range Flammability Rating Primary Application
Polypropylene (PP) Emerald Green / Black 0.90 – 0.91 25 – 30 MPa 1,100 – 1,400 -30°C to +90°C UL 94-HB (Standard) General industrial hydraulics, mobile equipment, machine tools
Polyamide 6 (PA6) Jet Black 1.13 – 1.15 65 – 80 MPa 2,200 – 2,800 -40°C to +120°C UL 94-V2 Heavy mobile machinery, outdoor construction, high-impact plant
Flame-Retardant PA66 Charcoal Black 1.18 – 1.22 75 – 90 MPa 2,600 – 3,200 -40°C to +130°C UL 94-V0 (Self-extinguishing) Ship engine rooms, passenger rail rolling stock (EN 45545), mining
Die-Cast Aluminum Natural Silver Gray 2.65 – 2.70 220 – 260 MPa 71,000 -40°C to +300°C Non-combustible Steel rolling mills, furnace lines, thermal oil circuits, foundries
Thermoplastic Elastomer (TPE) Black 1.10 – 1.20 8 – 12 MPa Shore 65A Hardness -40°C to +125°C UL 94-HB Vibration-damping cushion liners for DFB steel straps & unistrut
Fluoropolymer (PTFE) Pure White 2.15 – 2.20 20 – 35 MPa 400 – 600 -196°C to +260°C UL 94-V0 (Non-flammable) Low-friction sliding liners (μ < 0.08) for DFGJ-B marine GRE brackets

* Test Conditions & Limits: Values measured per DIN 3015 testing standards on St37 steel tube at 23°C with smooth-bore clamp bodies. The peak holding force of 244.5 kN applies specifically to Size Group 10 with aluminum body tightened to 600 N·m. For flexible hose applications or elastomer-cushioned supports, holding forces vary based on jacket durometer.

STRUCTURAL RIGIDITY · ANTI-RESONANCE GUIDELINE

Recommended Pipe Clamp Support Spacing (Span Distance)

Proper clamp spacing prevents pipe sagging, dampens mechanical fluid vibration, and eliminates natural harmonic resonance. Based on DIN 3015 engineering practices and ASME B31.3 process piping guidelines.

Tube O.D. Range (Metric) Nominal Pipe Size (Imperial) Standard Span (Steel Tubing) High-Vibration Lines (Mobile/Press) Elbow & Bend Clamping Rule
Φ6.0 – Φ12.7 mm 1/8" to 3/8" Tube 0.8 – 1.0 meters 0.5 – 0.7 meters Clamp within 100 mm of each tube bend
Φ15.0 – Φ22.0 mm 1/2" to 5/8" Tube 1.2 – 1.5 meters 0.8 – 1.0 meters Clamp within 150 mm of each tube bend
Φ25.0 – Φ38.0 mm 3/4" to 1 1/4" Pipe 1.5 – 2.0 meters 1.0 – 1.2 meters Clamp on both tangent points of the bend
Φ42.0 – Φ60.3 mm 1 1/2" to 2" Pipe 2.0 – 2.5 meters 1.5 – 1.8 meters Provide support bracket directly before valve
Φ76.1 – Φ114.3 mm 2 1/2" to 4" Pipe 2.5 – 3.2 meters 1.8 – 2.2 meters Heavy series DFH recommended
Φ133.0 – Φ219.1 mm 5" to 8" Pipe 3.2 – 4.0 meters 2.2 – 2.8 meters Heavy series DFH with reinforced weld base
Φ273.0 – Φ508.0 mm 10" to 20" Pipe 4.0 – 5.5 meters 2.8 – 3.5 meters 4-bolt ultra-heavy base (DFH*G16)

* Test Conditions & Limits: Values measured per DIN 3015 testing standards on St37 steel tube at 23°C with smooth-bore clamp bodies. The peak holding force of 244.5 kN applies specifically to Size Group 10 with aluminum body tightened to 600 N·m. For flexible hose applications or elastomer-cushioned supports, holding forces vary based on jacket durometer.

DIN 3015 PART 10 SPECIFICATIONS

Fastener Tightening Torques & Axial Holding Capacity

Tightening torques apply to standard carbon steel Grade 8.8 and stainless steel A4-70 bolts when clamping steel hydraulic tubes with virgin polypropylene (PP) shells.

Series Program Group Size Thread Spec Hex Socket Bolt Torque Hex Head Bolt Torque Stacking Bolt AF Torque Axial Shear Holding (kN)
DIN 3015-1 (Light DFL) Group L1 to L6 M6 × 1.0 8 N·m (6 lbf·ft) 8 N·m (6 lbf·ft) 8 N·m 1.6 – 4.2 kN
DIN 3015-1 (Light DFL) Group L7 to L8 M6 × 1.0 8 N·m (6 lbf·ft) 8 N·m (6 lbf·ft) 8 N·m 4.5 – 7.0 kN
DIN 3015-2 (Heavy DFH) Group H1 to H2 M10 × 1.5 12 N·m (9 lbf·ft) 12 N·m (9 lbf·ft) 12 N·m 1.6 – 11.6 kN (PP: 1.6–2.9 kN / AL: 10.5–11.6 kN)
DIN 3015-2 (Heavy DFH) Group H3 to H4 M10 / M12 25 N·m (18 lbf·ft) 30 N·m (22 lbf·ft) 30 N·m 23.5 – 38.2 kN
DIN 3015-2 (Heavy DFH) Group H5 to H6 M16 / M20 60 N·m (44 lbf·ft) 150 N·m (110 lbf·ft) 120 N·m 62.4 – 110.0 kN
DIN 3015-2 (Heavy DFH) Group H7 to H8 M24 / M30 200 N·m (147 lbf·ft) 350 N·m (258 lbf·ft) 350 N·m 30.0 – 84.5 kN (PP: 30–40 kN / AL: 68–84.5 kN)
DIN 3015-2 (Heavy DFH) Group H9 to H10 M30 × 3.5 300 N·m (221 lbf·ft) 600 N·m (442 lbf·ft) 500 N·m 45.0 – 244.5 kN (AL Group 10 peak: 244.5 kN)
DIN 3015-3 (Twin DFT) Group T1 to T2 M6 × 1.0 5 N·m (4 lbf·ft) 5 N·m (4 lbf·ft) 5 N·m 1.2 – 2.5 kN
DIN 3015-3 (Twin DFT) Group T3 to T5 M8 × 1.25 12 N·m (9 lbf·ft) 12 N·m (9 lbf·ft) 12 N·m 3.0 – 6.5 kN

* Test Conditions & Limits: Values measured per DIN 3015 testing standards on St37 steel tube at 23°C with smooth-bore clamp bodies. The peak holding force of 244.5 kN applies specifically to Size Group 10 with aluminum body tightened to 600 N·m. For flexible hose applications or elastomer-cushioned supports, holding forces vary based on jacket durometer.

TECHNICAL SOURCING & SPECIALIZED FABRICATION

Consult with the Delphi Clamps Engineering Desk.

Need custom clamping calculations, FEM stress simulation reports, material certification sheets (EN 10204 3.1), or specialized offshore coatings? Connect with Arthur HuangZhuo and our technical engineering team.

EXPORT COORDINATION DESK Mr. Arthur HuangZhuo

Director of Overseas Business

Phone / WeChat +86 185-8864-8174
Plant Address Funing Economic Development Zone, Yancheng, Jiangsu, China
DELPHI CLAMPS × DELPHI FITTINGS ECOSYSTEM